Introduction

Abnormal noise and excessive load are frequent troubleshooting problems for oil-sealed rotary vane vacuum pumps after startup. Many production lines will rush to replace the pump directly when encountering this fault, which brings unnecessary downtime and extra procurement cost. As a professional vacuum solution provider, Youcheng Zhixin has accumulated rich on-site service experience in vacuum pump assembly, pre-delivery inspection and after-sales maintenance. Today we sort out the root causes and corresponding solutions for this fault, helping engineers quickly locate the problem and restore stable operation of the vacuum system.

1. Motor Phase Loss Operation

Phase loss of three-phase motor is a high-risk electrical fault. When the motor runs lacking one phase, the current will surge sharply, accompanied by obvious buzzing noise and overload alarm. Solution: Check the power supply circuit, contactor and terminal wiring. If the cable is aging or loose, fasten or replace the cable in time. Youcheng Zhixin will carry out full electrical testing before delivery of vacuum pumps, to avoid hidden dangers of poor wiring.

2. Vacuum Pump Has Been Idle for a Long Time

If the pump is stored for a long time without running, the vacuum oil will stick, the rotor and vanes may stick to the pump cavity. The starting resistance rises, creating heavy load and abnormal knocking sound. Solution: Close the pump inlet, run the pump for a short time to heat up the pump body, let the oil circulate and lubricate the internal components gradually. Our technical team will provide pre-start guidance for long-stored equipment sold by Youcheng Zhixin.

3. Excessively High Ambient Temperature and Oil Temperature

Poor ventilation of the equipment room, continuous high-load operation will lead to rising oil temperature. The viscosity of vacuum oil drops, the lubrication condition deteriorates, and friction noise increases. Solution: Optimize the heat dissipation environment, control the working temperature within the range specified by the manual. Youcheng Zhixin’s vacuum pump station is equipped with customized heat dissipation structure for high-temperature working conditions.

4. Poor Vacuum Oil Quality

Inferior vacuum oil has unstable viscosity, poor oxidation resistance. It cannot form a complete oil film between friction pairs, resulting in dry friction and loud noise. Solution: Switch to synthetic vacuum oil. If necessary, select oil with slightly lower viscosity. Important reminder: Oil with too low viscosity will cause scratches inside the pump, so follow the recommended oil specification strictly. We will mark the matching oil model clearly for every set of equipment supplied by Youcheng Zhixin.

5. Blocked Exhaust Filter & Blackened Oil

The exhaust filter is blocked by oil sludge and impurities, which causes back pressure inside the pump. The oil turns black after long-term pollution, and the wear of internal components accelerates. Solution: Clean the whole vacuum pump, replace the oil filter element and exhaust filter. Regular filter replacement is one of the core maintenance items we recommend to our customers.

真空泵blog软文.jpeg

6. Vacuum Oil Has Not Been Changed for a Long Period

Vacuum oil will absorb moisture, dust and process gas during operation, and its performance will decline after aging. Long-term oil change cycle will aggravate pump load and noise. Solution: Drain the old oil completely, fill in new qualified vacuum oil and replace the oil filter together.

7. Foreign Matter Enters the Pump, Damaging Vanes and Bearings

If the front pipeline lacks a filter device, debris, dust and foreign substances may enter the pump cavity, scratch the rotary vanes and damage bearings, producing continuous metal collision noise. Solution: This kind of mechanical damage needs professional disassembly and overhaul. Youcheng Zhixin provides professional maintenance service for vacuum pumps, and we suggest installing a front filter to prevent foreign matter from entering the pump body.

Summary

Most abnormal noise and overload faults of vacuum pumps are not caused by pump scrapping. They can be divided into electrical problems, lubrication & oil problems, maintenance omission and mechanical damage. Standard daily maintenance and pre-start inspection can greatly reduce the failure rate. When you encounter vacuum system faults that are difficult to judge, welcome to consult the technical team of Youcheng Zhixin for professional vacuum support and solution customization.